26 13 13 Medium-voltage circuit breaker switchgear (gas-insulated ...

The base shall have two copper grounding pads located at diagonally opposite ... 8-16 UNC threaded brass studs to permit connection of a NEMA 2-hole ...

Installation Instructions for PBA10 Series

2 INSPECTION Examine the Enclosure carefully for shipping damage or for missing parts. The Damage and Shortage instruct ions packed with the unit outline the ...

DIVISION 26 - ELECTRICAL

Specify poles with integral hand hole. EXTERIOR ... 431and or CSL 3 Efficiency requirement, tested per NEMA TP-2: ... Provide isolation pads to prevent sound ...

IEC 309 NONMETALLIC PLUGS, RECEPTACLES INTERLOCKS

Cooper Crouse-Hinds recently introduced SpecOne TM, the only comprehensive line of hazardous area electrical products meeting all worldwide explosion protection standards.

Single-Phase, Pad-Mounted, Distribution Transformers

... meet the minimum efficiencies in Table 2 of NEMA ... shall be such that the knockout hole can be resealed after use. 2.10 All ... must be supplied with two (2) case grounding ...

SEFCOR Quick Reference Catalog

TYPE GTT2 One or Two Cables to Flat Two-Bolt Type A through-type grounding terminal for apparatus grounding pads having tapped holes on a NEMA 2-hole pattern.

Sleeve - CWD

Pin Sleeve Devices G-1- G-9 Pin Sleeve Devices Our Series 309 Watertight Pin and Sleeve Devices constitute one of the most complete lines of products in the industry, and ...

SECTION 26 05 00

NEMA National Electrical Manufacturers Association ... 600V copper THHN/THWN or XHHW-2 grounding ... on 3.5 inch (89 mm) concrete pads. ...

ISO SPECIFICATION

5.5 Grounding. 5.6 Primary ... applicable standards of the National Electrical Manufacturers Association ... terminals shall be tin-plated NEMA 4-hole pads ...

Raum Energy Inc. 70 Guyed Tower Foundation Construction Guide

70 Tower Foundation Construction Guide Raum Energy Inc. Proprietary 2009 2 WARNING! The foundation construction guidelines contained herein is a result of careful design and ...

Liquid-filled three-phase pad-mounted transformers ANSI/NEMA/IEEE ...

... 70 Gray 5.0BG7.0/0.4 u003E NEMA tank ground pads u003E hole for 45 through 500 kVA u003E 2 ... kVA above) 9 Nameplate 10 Grounding u003E 1-hole ground pad (75 - 500 kVA) u003E 2-hole ground pads (750 ...

Connectors Fittings

Our expanded family of Versa-Crimp dieless crimping tools gives you the capability you need for compression connections.

210-15 Primary or Secondary Unit Substation Transformers

Substation Transformers Electrical Apparatus Primary or Secondary Unit 210-15 GENERAL Cooper Power Systems Primary or Secondary Unit Substation Transformers are designed to meet ...

16340-1: MEDIUM VOLTAGE METAL-CLAD SWITCHGEAR (C/B SWITCHGEAR)

Ground pads, 2x 3.5 with provisions for NEMA 2-hole connectors, shall be welded on ... Enclosure grounding shall not depend on bolted connections ...

Manufacturer of Electrical Transformers or Reactors

There is access through a hand hole. A resealing pressure relief valve, with a cranking pressure of 10 psig is provided. NEMA grounding pads are provided in both ...

Title: Southern States CSH CSH-B

3.08 Ground Pads Two NEMA 2 hole ground pads shall be supplied for grounding the structure to the station ground grid. 4.0 MANUFACTURING REQUIREMENTS

IEC 309 Plugs, Receptacles, Interlocks Non-Hazardous Hazardous

1071 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2006 Cooper Crouse-Hinds 5P IEC 309 Hazardous Area Plugs Interlocks Class I, Zone 1 2, Div. 2, NEMA 4X, IP66 Easy to wire.

Vertical Interrupter Style Capacitor Switcher Product ...

3.08 Ground Pads Two NEMA 2 hole ground pads shall be supplied for grounding the structure to the station ground grid. 4.0 MANUFACTURING REQUIREMENTS

Section 26 05 11 - REQUIREMENTS FOR ELECTRICAL INSTALLATIONS

2.1 GROUNDING AND BONDING CONDUCTORS ... B. National Electrical Manufacturers Association (NEMA): ... round holes (not key-hole slots) in the fixture body. 2 ...

Electrical 2002 draft 1.doc

Use 2 hole straps in all areas of the building ... volt, 20 amp, multipole, electrically held NEMA 1 enclosure. 2. ... 2.02 GROUNDING AND BONDING PRODUCTS . A. Products: Of ...

MATL 6828.8, Primary Metering Cabinet, 27 kV, Three Phase, Padmount

seattle city light material standard standard number: page: date: rev: 6828.8 1 of 3 may 21, 1999 new originator standards coordinator standards supervisor unit director primary ...

Three Phase Padmounted Transformer Specifications for Customers

... Specification, D14-07-004 Rev. 2, Concrete Pads ... terminals shall be made with a 2-hole NEMA ... CONTINUE THE #2 COPPER TO THE GROUND PAD. SEE GROUNDING DIAGRAM.

SECTION 16060

Grounding and Bonding for electrical systems ... copper stock with (1 + 3/4) x 2 bolt hole pattern to accept NEMA ... plates, and equipment ground pads.

THREE PHASE PADMOUNTED TRANSFORMER TRAINING

... Color Coding 120/208v or 277/480v Integrated/Isolat ed 8 Sets Max Grounding Pads ... rated for 200 ampere) Three Lightning Arrestor Elbows With Three NEMA 2-Hole ...